Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
PS21965-4S
Intellimod? Module
Dual-In-Line Intelligent Power Module
20 Amperes/600 Volts
Electrical and Mechanical Characteristics, T j = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage
Diode Forward Voltage
Inductive Load Switching Times
Collector Cutoff Current
V CE(sat)
V EC
t on
t rr
t C(on)
t off
t C(off)
I CES
V D = V DB = 15V, I C = 20A, V IN = 5V, T j = 25°C
V D = V DB = 15V, I C = 20A, V IN = 5V, T j = 125°C
-I C = 20A, V IN = 0V
V CC = 300V, V D = V DB = 15V,
I C = 20A, T j = 125°C,
V IN = 0 ? 5V, Inductive Load,
V CE = V CES , T j = 25°C
V CE = V CES , T j = 125°C
0.70
1.70
1.80
1.90
1.30
0.30
0.50
1.60
0.40
2.20
2.30
2.40
1.90
0.75
2.20
0.75
1.0
10
Volts
Volts
Volts
μs
μs
μs
μs
μs
mA
mA
Control Sector
Circuit Current
I D
V IN = 5V
Total of V P1 -V NC , V N1 -V NC
2.80
mA
V D = V DB = 15V
V IN = 0V
V UFB -U, V VFB -V, V WFB -W
Total of V P1 -V NC , V N1 -V NC
V UFB -U, V VFB -V, V WFB -W
0.55
2.80
0.55
mA
mA
mA
Fault Output Voltage
Input Current
Short Circuit Trip Level*
Supply Circuit Under-voltage
Fault Output Pulse Width**
ON Threshold Voltage
OFF Threshold Voltage
ON/OFF Threshold Hysteresis Voltage
V FOH
V FOL
I IN
V SC(ref)
UV DBt
UV DBr
UV Dt
UV Dr
t FO
V th(on)
V th(off)
V th(hys)
V SC = 0V, F O Terminal Pull-up to 5V by 10k Ω
V SC = 1V, I FO = 1mA
V IN = 5V
V D = 15V*
Trip Level, T j ≤ 125°C
Reset Level, T j ≤ 125°C
Trip Level, T j ≤ 125°C
Reset Level, T j ≤ 125°C
Applied between
U P , V P , W P -V NC,
U N , V N , W N -V NC
4.9
0.70
0.43
10.0
10.5
10.3
10.8
20
0.8
0.35
1.00
0.48
2.1
1.3
0.65
0.95
1.50
0.53
12.0
12.5
12.5
13.0
2.6
Volts
Volts
mA
Volts
Volts
Volts
Volts
Volts
μs
Volts
Volts
Volts
* Short Circuit protection is functioning only for the low-arms. Please select the value of the external shunt resistor such that the SC trip level is less than 1.7 times the current rating.
**Fault signal is asserted only for a UV or SC condition on the low side. On a SC fault the FO duration will be 20μsec. On a UV condition the fault signal will be asserted as long as the
UV condition exists or for 20μsec, whichever is longer.
Rev. 12/09
3
相关PDF资料
PS21A79 MOD IPM 600V 50A LARGE DIP
PS21A7A MOD IPM 600V 75A LARGE DIP
PS22052 MOD IPM 1200V 5A DIP
PS22053 MOD IPM 1200V 10A DIP
PS22054 MOD IPM 1200V 15A DIP
PS22056 MOD IPM 1200V 25A DIP
PS22A72 MOD IPM 1200V 5A LARGE DIP
PS22A73 MOD IPM 1200V 10A LARGE DIP
相关代理商/技术参数
PS21965-4S_08 制造商:MITSUBISHI 制造商全称:Mitsubishi Electric Semiconductor 功能描述:Dual-In-Line Package Intelligent Power Module
PS21965-4W 制造商:MITSUBISHI 制造商全称:Mitsubishi Electric Semiconductor 功能描述:600V/20A low-loss CSTBTTM inverter bridge for three phase DC-to-AC power conversion
PS21965-A 制造商:POWEREX 制造商全称:Powerex Power Semiconductors 功能描述:Dual-In-Line Intelligent Power Module 20 Amperes/600 Volts
PS21965-AT 制造商:MITSUBISHI 制造商全称:Mitsubishi Electric Semiconductor 功能描述:Dual-In-Line Package Intelligent Power Module TRANSFER-MOLD TYPE INSULATED TYPE
PS21965-C 制造商:POWEREX 制造商全称:Powerex Power Semiconductors 功能描述:Dual-In-Line Intelligent Power Module 20 Amperes/600 Volts
PS21965-CT 制造商:MITSUBISHI 制造商全称:Mitsubishi Electric Semiconductor 功能描述:Dual-In-Line Package Intelligent Power Module TRANSFER-MOLD TYPE INSULATED TYPE
PS21965-ST 制造商:Mitsubishi Electric 功能描述:POWER IPM TRANSISTOR
PS21965-ST_09 制造商:MITSUBISHI 制造商全称:Mitsubishi Electric Semiconductor 功能描述:Dual-In-Line Package Intelligent Power Module TRANSFER-MOLD TYPE INSULATED TYPE